DC6.5-25V Cycle Delay Relay Module 0.1s-9999min Adjustable Time Control Switch Multifunctional Motor Forward Reverse Controller Vue Default Title

DC 6.5-25V Cycle Timer Relay Module – Motor Forward/Reverse Control

Default Title
Sale price  $61.99 Regular price $75.99
Skip to product information
DC6.5-25V Cycle Delay Relay Module 0.1s-9999min Adjustable Time Control Switch Multifunctional Motor Forward Reverse Controller Vue Default Title

DC 6.5-25V Cycle Timer Relay Module – Motor Forward/Reverse Control

Sale price  $61.99 Regular price $75.99
Default TitleDefault Title

DC Cycle Delay Relay Module – Adjustable Timer & Motor Direction Controller

Take precise control of your DC/AC motor applications with this versatile Cycle Delay Relay Module. Featuring an ultra-wide timing range of 0.1 seconds to 9,999 minutes, dual power supply inputs, and multiple programmable function modes, this compact module is ideal for automation projects, DIY electronics, robotics, and industrial motor control. Made in Mainland China.

Key Features

  • Dual Power Supply: Accepts DC 6.5–25V (Power Supply 1) or DC 5V (Power Supply 2) — note: only one supply should be connected at a time.
  • Wide Timing Range: Set delays from 0.1–999.9 seconds, 1–9999 seconds, or 1–9999 minutes for maximum flexibility.
  • Cycle Control: Choose no cycle, 2–99 cycles, or continuous (always cycle) operation.
  • Three Input Control Ports: Forward (FWD), Reverse (REV), and Stop (STOP) for full directional motor management.
  • Two Trigger Modes: Low-Pulse trigger and Low-Level trigger to suit your circuit design.
  • Three LED Indicators: Forward (F LED), Reverse (R LED), and Stop (S LED) for clear at-a-glance status monitoring.
  • Energy-Saving Mode: Reduces standby current to just 7mA by turning off the digital display and LED indicators while keeping all functions active.
  • Six Programmable Function Modes (F-01, F-02, F-11, F-12, F-21, F-22): Covers auto-cycle, trigger-start, trigger-reversible, and level-hold operation for a wide variety of automation scenarios.
  • Relay Load: Supports up to 5A load current for reliable switching.

Specifications

Power Supply DC 6.5–25V or DC 5V (one at a time)
Working Current 83mA (Normal Mode); 44mA (Energy-Saving Mode)
Standby Current 41mA (Normal Mode); 7mA (Energy-Saving Mode)
Relay Load Current < 5A (recommended)
Delay Time Range 0.1–999.9s / 1–9999s / 1–9999 min
Time Units 0.1 Second, 1 Second, 1 Minute
Dimensions 8 × 5 cm (3.2 × 2 in)
Weight Approx. 51g (1.8 oz)
Country of Origin Made in Mainland China

Port Reference

  • DC 5.5 Female Jack: Power Supply 2 (DC 5V)
  • VIN: Power Supply 1 positive (DC 6.5–25V)
  • GND: Power Supply 1 negative
  • FWD: Forward input control
  • REV: Reverse input control
  • STOP: Stop input control
  • M+: Motor positive terminal
  • M−: Motor negative terminal
  • P+: Motor power supply positive
  • P−: Motor power supply negative

Timer Settings

  • T1: Forward Timer
  • T2: Reverse Timer
  • T3: Stop (pause) Timer

Function Modes Overview

  • F-01: Auto-cycle on power-up — forward T1 → stop T3 → reverse T2, repeated N times. STOP port halts immediately.
  • F-02: Same as F-01 but requires a FWD or REV trigger to begin the cycle.
  • F-11 (Trigger Reversible 1): FWD trigger runs motor forward for T1 then auto-stops; REV trigger runs motor reverse for T2 then auto-stops. STOP halts at any time. Direction change mid-cycle includes a T3 pause for protection.
  • F-12 (Trigger Reversible 2): Similar to F-11 but other ports are locked during the active delay; only STOP can interrupt.
  • F-21: Level-hold mode — motor runs forward while FWD port is held low; runs reverse while REV is held low. Simultaneous FWD + REV is not permitted; STOP port inactive.
  • F-22: Same as F-21 but STOP port is active and can halt the motor immediately.

Factory Reset & Energy-Saving Mode

To restore factory settings, press the "++" and "−−" buttons simultaneously for 5 seconds. To toggle Energy-Saving Mode (display off, reduced current), press and hold "OK" for 5 seconds.

What's in the Box

  • 1× Cycle Delay Relay Module

Learn More About Electrical Safety

For guidance on safe wiring practices and electrical standards, visit the OSHA Electrical Safety resource page.

Frequently Asked Questions

Q: What is the maximum voltage this cycle delay relay module supports?

A: This relay module supports a primary power supply of DC 6.5–25V (via VIN/GND terminals) or an alternative DC 5V supply via the 5.5mm DC jack. Only one power supply should be connected at a time. The relay load itself can handle currents up to 5A.

Q: Can I use this module to automate a motor to run forward and reverse on a timed schedule?

A: Yes! Function mode F-01 is specifically designed for this: after power-up, the motor runs forward for the T1 duration, pauses for T3, then runs in reverse for T2, and repeats this cycle N times (or indefinitely). You can set each time independently from 0.1 seconds up to 9,999 minutes.

Q: What is the difference between the Normal Mode and Energy-Saving Mode?

A: In Normal Mode the standby current is 41mA and working current is 83mA, with the LED display and indicators fully active. In Energy-Saving Mode, the digital display and LED indicators are turned off, reducing standby current to 7mA and working current to 44mA — all timing and relay functions continue to operate normally.

Q: Is this module compatible with both DC and AC motors?

A: Yes, this is a multifunctional controller suitable for both DC and AC motor forward/reverse control, as long as the motor's current requirements stay within the relay's recommended 5A load limit.