{"product_id":"time-delay-module-magnetic-lock-access-control-hy1d","title":"Time Delay Module for Magnetic Lock Access Control – HY1D","description":"\n\u003ch2\u003eLUCKING DOOR HY1D Power Supply Time Delay Module\u003c\/h2\u003e\n\u003cp\u003eUpgrade your access control system with the \u003cstrong\u003eLUCKING DOOR HY1D Time Delay Module\u003c\/strong\u003e — a compact, reliable power board designed to work seamlessly with fail-safe magnetic locks and electric locks. With an adjustable delay of \u003cstrong\u003e2 to 20 seconds\u003c\/strong\u003e, this module gives you precise control over lock timing, ensuring smooth and secure door operation in offices, apartment buildings, server rooms, and more.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Time Delay:\u003c\/strong\u003e Set the delay anywhere from 2 to 20 seconds to match your specific access control needs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Operates on DC 12V–18V, making it compatible with most standard access control power supplies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelay-Controlled NC Output:\u003c\/strong\u003e Normally Closed (NC) output via relay control — designed exclusively for \u003cstrong\u003efail-safe locks\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Form Factor:\u003c\/strong\u003e Measures just 38mm × 53mm (approx. 4.3 × 4.3 × 2 cm), fitting neatly into standard access control enclosures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNo Hazardous Chemicals:\u003c\/strong\u003e Contains no high-concern chemicals for safe installation and long-term use.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEasy Integration:\u003c\/strong\u003e Designed as a plug-and-play power board for existing magnetic lock and electric lock setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCKING DOOR\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHY1D\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC 12V – DC 18V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Delay Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 – 20 seconds (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally Closed (NC) – Relay Control (Fail-Safe Locks Only)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38mm × 53mm (PCB); approx. 4.3 × 4.3 × 2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Chemicals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in Mainland China\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat Is This Module Used For?\u003c\/h3\u003e\n\u003cp\u003eThis time delay module acts as an intermediary power board between your access control system and your fail-safe magnetic or electric lock. When an access event is triggered (card swipe, keypad, etc.), the module introduces a programmable delay before cutting or restoring power to the lock — preventing abrupt lock cycling and protecting both the lock hardware and the door frame over time.\u003c\/p\u003e\n\n\u003cp\u003e⚠️ \u003cstrong\u003eImportant:\u003c\/strong\u003e This module is designed \u003cstrong\u003eONLY for fail-safe locks\u003c\/strong\u003e (locks that are open when power is off). It is \u003cstrong\u003enot compatible\u003c\/strong\u003e with fail-secure locks.\u003c\/p\u003e\n\n\u003ch3\u003eIdeal Applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOffice and commercial building access control systems\u003c\/li\u003e\n  \u003cli\u003eApartment and residential intercom door systems\u003c\/li\u003e\n  \u003cli\u003eServer room and secure area entry points\u003c\/li\u003e\n  \u003cli\u003eAny installation using a DC-powered fail-safe magnetic or electric lock\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor more information on best practices for electronic access control and building security, visit the U.S. Consumer Product Safety Commission (CPSC).\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: What type of locks is the HY1D time delay module compatible with?\u003c\/h4\u003e\n\u003cp\u003eA: The HY1D time delay module is designed exclusively for \u003cstrong\u003efail-safe locks\u003c\/strong\u003e — meaning locks that default to the open (unlocked) position when power is removed. It is NOT compatible with fail-secure locks. Common compatible types include fail-safe magnetic locks and electric strike locks used in standard access control systems.\u003c\/p\u003e\n\n\u003ch4\u003eQ: How do I adjust the time delay on this module?\u003c\/h4\u003e\n\u003cp\u003eA: The module features an on-board adjustable mechanism (typically a potentiometer or DIP switch) that allows you to set the delay anywhere between 2 and 20 seconds. Simply turn or adjust the control to your desired delay time before or after installation.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What power supply do I need for this delay module?\u003c\/h4\u003e\n\u003cp\u003eA: The HY1D operates on DC 12V to DC 18V input. A standard 12V DC access control power supply is the most common choice and is fully compatible with this module.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Can I use this module with my existing access control system?\u003c\/h4\u003e\n\u003cp\u003eA: Yes. This module is designed as a supplementary power board that integrates between your existing access control power supply and your fail-safe lock. It uses a normally closed (NC) relay output, which is the standard configuration for most access control wiring setups.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What type of locks is the HY1D time delay module compatible with?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The HY1D time delay module is designed exclusively for fail-safe locks — meaning locks that default to the open (unlocked) position when power is removed. It is NOT compatible with fail-secure locks. Common compatible types include fail-safe magnetic locks and electric strike locks used in standard access control systems.\"}}, {\"@type\": \"Question\", \"name\": \"How do I adjust the time delay on this module?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The module features an on-board adjustable mechanism (typically a potentiometer or DIP switch) that allows you to set the delay anywhere between 2 and 20 seconds. Simply turn or adjust the control to your desired delay time before or after installation.\"}}, {\"@type\": \"Question\", \"name\": \"What power supply do I need for this delay module?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The HY1D operates on DC 12V to DC 18V input. A standard 12V DC access control power supply is the most common choice and is fully compatible with this module.\"}}, {\"@type\": \"Question\", \"name\": \"Can I use this module with my existing access control system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. This module is designed as a supplementary power board that integrates between your existing access control power supply and your fail-safe lock. It uses a normally closed (NC) relay output, which is the standard configuration for most access control wiring setups.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Electronics \u0026 Tech\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/collections\/electronics-tech\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"Time Delay Module for Magnetic Lock Access Control – HY1D\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/products\/time-delay-module-magnetic-lock-access-control-hy1d\"}]}\u003c\/script\u003e","brand":"Vue","offers":[{"title":"HY1D","offer_id":48753083187392,"sku":"14:10#HY1D","price":31.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0772\/9338\/7968\/files\/H07d3a1f142154a1d8e0c83fddf686373d.webp?v=1786266523","url":"https:\/\/vueselect.com\/products\/time-delay-module-magnetic-lock-access-control-hy1d","provider":"Vue","version":"1.0","type":"link"}