{"product_id":"single-phase-voltage-protector-32a-40a-63a-adjustable-reset-switch","title":"Single-Phase Voltage Protector 32A\/40A\/63A Adjustable Reset Switch","description":"\n\u003ch2\u003eSingle-Phase Adjustable Voltage Protector — 32A \/ 40A \/ 63A\u003c\/h2\u003e\n\u003cp\u003eKeep your home appliances and electrical equipment safe from damaging voltage fluctuations with this compact, adjustable single-phase voltage protector. Whether voltage spikes too high or dips too low, this smart protective reset switch automatically cuts power to your circuit and reconnects it once stable voltage is restored — all without manual intervention.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTri-Current Options:\u003c\/strong\u003e Available in 32A, 40A, and 63A ratings to suit a wide range of residential and light commercial circuits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Under-Voltage Cut-Off:\u003c\/strong\u003e Set your own threshold anywhere from 120V to 200V (factory default: 170V) to match your specific needs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Over-Voltage Cut-Off:\u003c\/strong\u003e Configurable from 230V to 300V (factory default: 270V) for flexible circuit protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Overcurrent Protection:\u003c\/strong\u003e Current cut-off threshold is user-adjustable from 1A to 63A (factory default: 63A).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Reset Switch:\u003c\/strong\u003e Automatically reconnects the circuit once voltage returns to a safe, stable range — no need to manually reset.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLong Service Life:\u003c\/strong\u003e Rated for ≥ 100,000 electrical and mechanical cycles, built for lasting reliability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMini Form Factor:\u003c\/strong\u003e Compact design fits neatly into standard distribution boards and electrical enclosures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC single-phase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e32A \/ 40A \/ 63A (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUnder-Voltage Cut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e120V–200V adjustable (default: 170V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eOver-Voltage Cut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e230V–300V adjustable (default: 270V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eOvercurrent Cut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e1A–63A adjustable (default: 63A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eElectrical \u0026amp; Mechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e≥ 100,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMini\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMade in China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat's in the Box?\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 × Single-Phase Over\/Under Voltage Protective Reset Switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Safety Note\u003c\/h3\u003e\n\u003cp\u003eThis device should be installed by a qualified electrician in accordance with local electrical codes and standards. Always switch off the main supply before installation. For general electrical safety guidance, visit the U.S. Consumer Product Safety Commission – Electrical Safety resource center.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eNote: Due to monitor calibration differences, product color may vary slightly from images. Please allow ±1mm measurement tolerance due to manual measurement methods.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: What does an adjustable voltage protector do, and why do I need one?\u003c\/h4\u003e\n\u003cp\u003eA: An adjustable voltage protector monitors your circuit's incoming voltage in real time. If the voltage rises above or falls below your set thresholds — or if the current draw exceeds your configured limit — the device automatically cuts power to the connected circuit, safeguarding appliances and equipment from damage caused by voltage instability. Once the voltage returns to a safe range, it reconnects automatically.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Can I adjust the cut-off thresholds myself, or are they fixed at the factory defaults?\u003c\/h4\u003e\n\u003cp\u003eA: All thresholds are fully user-adjustable. The under-voltage cut-off can be set anywhere from 120V to 200V, the over-voltage cut-off from 230V to 300V, and the overcurrent threshold from 1A to 63A. The factory defaults (170V \/ 270V \/ 63A) are pre-configured for general household use but can be changed to suit your specific installation requirements.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Which current rating should I choose — 32A, 40A, or 63A?\u003c\/h4\u003e\n\u003cp\u003eA: Choose a rating that matches or slightly exceeds the maximum expected load on your circuit. For standard household sub-circuits, 32A is often sufficient. For heavier loads such as electric cooktops, air conditioning units, or small workshops, 40A or 63A may be more appropriate. When in doubt, consult a licensed electrician.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Is this protector compatible with standard DIN rail enclosures?\u003c\/h4\u003e\n\u003cp\u003eA: Yes. The mini form factor is designed to be compatible with standard electrical distribution boards and DIN rail enclosures, making installation straightforward for qualified electricians.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does an adjustable voltage protector do, and why do I need one?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"An adjustable voltage protector monitors your circuit's incoming voltage in real time. If the voltage rises above or falls below your set thresholds — or if the current draw exceeds your configured limit — the device automatically cuts power to the connected circuit, safeguarding appliances and equipment from damage caused by voltage instability. Once the voltage returns to a safe range, it reconnects automatically.\"}}, {\"@type\": \"Question\", \"name\": \"Can I adjust the cut-off thresholds myself, or are they fixed at the factory defaults?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"All thresholds are fully user-adjustable. The under-voltage cut-off can be set anywhere from 120V to 200V, the over-voltage cut-off from 230V to 300V, and the overcurrent threshold from 1A to 63A. The factory defaults (170V \/ 270V \/ 63A) are pre-configured for general household use but can be changed to suit your specific installation requirements.\"}}, {\"@type\": \"Question\", \"name\": \"Which current rating should I choose — 32A, 40A, or 63A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Choose a rating that matches or slightly exceeds the maximum expected load on your circuit. For standard household sub-circuits, 32A is often sufficient. For heavier loads such as electric cooktops, air conditioning units, or small workshops, 40A or 63A may be more appropriate. When in doubt, consult a licensed electrician.\"}}, {\"@type\": \"Question\", \"name\": \"Is this protector compatible with standard DIN rail enclosures?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The mini form factor is designed to be compatible with standard electrical distribution boards and DIN rail enclosures, making installation straightforward for qualified electricians.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Fasteners \u0026 Electrical\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/collections\/fasteners-electrical\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"Single-Phase Voltage Protector 32A\/40A\/63A Adjustable Reset Switch\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/products\/single-phase-voltage-protector-32a-40a-63a-adjustable-reset-switch\"}]}\u003c\/script\u003e","brand":"Vue","offers":[{"title":"32A","offer_id":48750184792256,"sku":"567:200001994","price":50.99,"currency_code":"USD","in_stock":true},{"title":"63A","offer_id":48750184825024,"sku":"567:203122981","price":50.99,"currency_code":"USD","in_stock":true},{"title":"40A","offer_id":48750184857792,"sku":"567:200002043","price":50.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0772\/9338\/7968\/files\/Se5bd6e5a93a74c219878d8083952ce61G.webp?v=1786224221","url":"https:\/\/vueselect.com\/products\/single-phase-voltage-protector-32a-40a-63a-adjustable-reset-switch","provider":"Vue","version":"1.0","type":"link"}