{"product_id":"multi-channel-wiegand-converter-splitter-hub-2in1out-4in1out-1in2out","title":"Wiegand Converter Splitter Hub – 2In1Out, 4In1Out, 1In2Out WG26–WG80","description":"\u003ch2\u003eMulti-Channel Wiegand Converter Splitter Hub\u003c\/h2\u003e\n\u003cp\u003eExpand and streamline your access control system with this versatile \u003cstrong\u003eMulti-Channel Wiegand Converter Splitter Hub\u003c\/strong\u003e (Model: WGHUB) by LIHTNE. Designed for security integrators, facility managers, and access control professionals, this compact adapter board lets you multiply, split, or combine Wiegand card reader signals across multiple access control boards — all without adding complexity or extra wiring overhead.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Configuration Modes:\u003c\/strong\u003e Choose from 2-In\/1-Out, 4-In\/1-Out, or 1-In\/2-Out topologies to match your exact installation requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Wiegand Protocol Support:\u003c\/strong\u003e Compatible with WG26 through WG80 by default, including WG26, WG32, WG34, WG35, WG36, WG37, WG40, WG42, WG44, WG66, WG80, and keyboard code input.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Authentication (Face + Card):\u003c\/strong\u003e Connect a face recognition terminal and a card reader to the adapter board simultaneously. The hub compares both Wiegand signals and only passes the output to the access control board when both credentials match — enabling reliable two-factor entry verification.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Reader Aggregation (4-In\/1-Out):\u003c\/strong\u003e Connect up to 4 card readers at the same time. Swipe data from readers 1–4 is sequentially forwarded to the access control board, perfect for high-traffic environments where many people need to badge in simultaneously.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSignal Splitting (1-In\/2-Out):\u003c\/strong\u003e Route one card reader's output to two separate access control boards at once, with fully customizable card number forwarding rules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRS485 Interface (Optional):\u003c\/strong\u003e Both Wiegand signals can be output via the same RS485 interface. RS485 communication parameters: 9600, N, 8, 1.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFast Card Swipe Response:\u003c\/strong\u003e Supports swipe intervals of \u0026gt;150ms per card reader for smooth, rapid throughput.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Power Input:\u003c\/strong\u003e Operates on +9V to +24V DC at just 30mA — low power consumption, easy to integrate into existing power supplies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOperating Modes at a Glance\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background:#f4f4f4;\"\u003e\n      \u003cth style=\"padding:8px; border:1px solid #ddd;\"\u003eMode\u003c\/th\u003e\n      \u003cth style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n      \u003cth style=\"padding:8px; border:1px solid #ddd;\"\u003eIdeal Use Case\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e2-In \/ 1-Out\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e2 card readers → 1 access control board\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConvert a 4-door one-way board to 4-door two-way swiping\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e4-In \/ 1-Out\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e4 card readers → 1 access control board\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eHigh-volume access points; extends reader capacity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e1-In \/ 2-Out\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e1 card reader → 2 access control boards\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSimultaneous dual-board credential forwarding\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDual Auth\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eFace recognition + card reader → 1 board\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eTwo-factor verification for secured areas\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e LIHTNE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e WGHUB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e +9V ~ +24V DC, 30mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupported Protocols:\u003c\/strong\u003e WG26 \/ WG32 \/ WG34 \/ WG35 \/ WG36 \/ WG37 \/ WG40 \/ WG42 \/ WG44 \/ WG66 \/ WG80 + keyboard code\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSwipe Interval:\u003c\/strong\u003e \u0026gt;150ms per reader\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRS485 Parameters:\u003c\/strong\u003e 9600, N, 8, 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptional Output:\u003c\/strong\u003e Both WG signals via single RS485 interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Choose This Wiegand Hub?\u003c\/h3\u003e\n\u003cp\u003eWhether you're upgrading an existing access control infrastructure or designing a new multi-door security system, this Wiegand splitter\/converter hub saves installation time, reduces hardware costs, and adds powerful dual-authentication capabilities without requiring a full system overhaul. Its broad protocol compatibility ensures it works with virtually any modern Wiegand-based access control panel.\u003c\/p\u003e\n\n\u003cp\u003eFor further guidance on physical access control system standards and best practices, refer to the NIST Guidelines on Smart Card Technology.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: What Wiegand protocols does this multi-channel Wiegand converter hub support?\u003c\/h4\u003e\n\u003cp\u003eA: The WGHUB supports WG26 through WG80 by default, including WG26, WG32, WG34, WG35, WG36, WG37, WG40, WG42, WG44, WG66, WG80, and keyboard code input — covering the vast majority of modern Wiegand-based card readers and access control panels.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Can this hub enable dual authentication with a face recognition device and a card reader?\u003c\/h4\u003e\n\u003cp\u003eA: Yes. When a face recognition terminal and a card reader are both connected to the adapter board, the hub compares the Wiegand output from each device. Only when both credential signals match is the combined output forwarded to the access control board, enabling reliable two-factor entry verification.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What power supply does the Wiegand splitter hub require?\u003c\/h4\u003e\n\u003cp\u003eA: The hub operates on a +9V to +24V DC input at only 30mA, making it compatible with most standard access control power supplies and easy to integrate into existing installations.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Can I customize which access control board receives the card data in 1-In\/2-Out mode?\u003c\/h4\u003e\n\u003cp\u003eA: Yes. In the 1-In\/2-Out configuration, card number forwarding rules can be fully customized to meet specific installation or security requirements, giving you complete control over which boards receive credential data.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Is RS485 communication supported?\u003c\/h4\u003e\n\u003cp\u003eA: Yes, RS485 is optionally supported, allowing both Wiegand signals to be output through a single RS485 interface with communication parameters of 9600, N, 8, 1, suitable for longer cable runs and networked installations.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What Wiegand protocols does this multi-channel Wiegand converter hub support?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The WGHUB supports WG26 through WG80 by default, including WG26, WG32, WG34, WG35, WG36, WG37, WG40, WG42, WG44, WG66, WG80, and keyboard code input — covering the vast majority of modern Wiegand-based card readers and access control panels.\"}}, {\"@type\": \"Question\", \"name\": \"Can this hub enable dual authentication with a face recognition device and a card reader?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. When a face recognition terminal and a card reader are both connected to the adapter board, the hub compares the Wiegand output from each device. Only when both credential signals match is the combined output forwarded to the access control board, enabling reliable two-factor entry verification.\"}}, {\"@type\": \"Question\", \"name\": \"What power supply does the Wiegand splitter hub require?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The hub operates on a +9V to +24V DC input at only 30mA, making it compatible with most standard access control power supplies and easy to integrate into existing installations.\"}}, {\"@type\": \"Question\", \"name\": \"Can I customize which access control board receives the card data in 1-In\/2-Out mode?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. In the 1-In\/2-Out configuration, card number forwarding rules can be fully customized to meet specific installation or security requirements, giving you complete control over which boards receive credential data.\"}}, {\"@type\": \"Question\", \"name\": \"Is RS485 communication supported?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, RS485 is optionally supported, allowing both Wiegand signals to be output through a single RS485 interface with communication parameters of 9600, N, 8, 1, suitable for longer cable runs and networked installations.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Electronics \u0026 Tech\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/collections\/electronics-tech\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"Wiegand Converter Splitter Hub – 2In1Out, 4In1Out, 1In2Out WG26–WG80\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/products\/multi-channel-wiegand-converter-splitter-hub-2in1out-4in1out-1in2out\"}]}\u003c\/script\u003e","brand":"Vue","offers":[{"title":"1in 2 out","offer_id":48752684171456,"sku":"14:173#1in 2 out","price":147.99,"currency_code":"USD","in_stock":true},{"title":"4in 1 out","offer_id":48752684204224,"sku":"14:175#4in 1 out","price":147.99,"currency_code":"USD","in_stock":true},{"title":"2In 1 out","offer_id":48752684236992,"sku":"14:350852#2In 1 out","price":147.99,"currency_code":"USD","in_stock":true},{"title":"2factor verification","offer_id":48752684269760,"sku":"14:10#2factor verification","price":147.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0772\/9338\/7968\/files\/Hf04e2a91977e411b8d8729cd0ec2f34bH.webp?v=1786253769","url":"https:\/\/vueselect.com\/products\/multi-channel-wiegand-converter-splitter-hub-2in1out-4in1out-1in2out","provider":"Vue","version":"1.0","type":"link"}