{"product_id":"k-type-thermocouple-temperature-transmitter-module-0-5v-0-10v","title":"K-Type Thermocouple Transmitter Module | 0-5V \u0026 0-10V Output","description":"\n\u003ch2\u003eK-Type Thermocouple to Voltage Transmitter Module — Precise Linear Signal Conversion\u003c\/h2\u003e\n\u003cp\u003eConvert K-type thermocouple readings into clean, linear analog voltage signals with this compact Temperature Transmitter Module. Offering selectable output ranges of \u003cstrong\u003e0–5V\u003c\/strong\u003e or \u003cstrong\u003e0–10V\u003c\/strong\u003e, it is ideal for engineers, makers, and automation professionals who need reliable temperature-to-voltage conversion for PLCs, data loggers, SCADA systems, and remote monitoring equipment.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Temperature Measurement Range:\u003c\/strong\u003e -100°C to +1100°C — suitable for demanding industrial and laboratory applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Output Modes:\u003c\/strong\u003e Selectable via onboard J1 pad — open circuit for 0.00V–5.00V output; short circuit for 0.00V–10.00V output (default: open circuit \/ 0–5V).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e 0.0041666 V\/°C (0–5V mode) | 0.0083333 V\/°C (0–10V mode) for fine-grained, accurate readings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad Power Supply Compatibility:\u003c\/strong\u003e Operates on 9V–24V DC (use ≥15V supply when selecting the 0–10V output range).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra-Compact Form Factor:\u003c\/strong\u003e Only 26mm × 23mm × 10mm — fits easily into enclosures and custom PCB assemblies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Interface Terminals:\u003c\/strong\u003e Clear labelled connectors for power (24V\/G), thermocouple input (I+\/I-), and analog signal output (OUT\/G).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eModule Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9V – 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK-Type Thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00V – 5.00V \/ 0.00V – 10.00V (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-100°C to +1100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution (0–5V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0041666 V\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution (0–10V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0083333 V\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26mm (L) × 23mm (W) × 10mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in Mainland China\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInterface Pin Reference\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e24V\u003c\/strong\u003e — Positive power input (9V–24V DC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eG\u003c\/strong\u003e — Power ground\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eI+\u003c\/strong\u003e — Thermocouple positive electrode\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eI–\u003c\/strong\u003e — Thermocouple negative electrode\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOUT\u003c\/strong\u003e — Analog signal output (0–5V or 0–10V)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eG\u003c\/strong\u003e — Signal ground\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTemperature Calculation Formula\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003e(Output Voltage (V) ÷ Resolution) − 100°C = Measured Temperature (°C)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExample (0–5V mode):\u003c\/strong\u003e Output = 2.5V → (2.5 ÷ 0.0041666) − 100 = 500°C\u003c\/p\u003e\n\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial process temperature monitoring\u003c\/li\u003e\n  \u003cli\u003ePLC and SCADA analog input integration\u003c\/li\u003e\n  \u003cli\u003eRemote data acquisition and control systems\u003c\/li\u003e\n  \u003cli\u003eDIY electronics and Arduino\/Raspberry Pi projects\u003c\/li\u003e\n  \u003cli\u003eLaboratory and research instrumentation\u003c\/li\u003e\n  \u003cli\u003eFurnace, kiln, and oven temperature feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor guidance on safe wiring practices for electronic modules in industrial environments, refer to \u003ca href=\"https:\/\/www.osha.gov\/electrical\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOSHA Electrical Safety Standards\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: What is the difference between the 0–5V and 0–10V output modes on this K-type temperature transmitter module?\u003c\/h4\u003e\n\u003cp\u003eA: The output mode is selected via the onboard J1 pad. With the pad in the open-circuit (default) state, the module outputs a 0.00V–5.00V analog signal. When the J1 pad is short-circuited, the output range switches to 0.00V–10.00V. Note that when using the 0–10V output range, your power supply voltage must be at least 15V DC to ensure accurate results.\u003c\/p\u003e\n\u003ch4\u003eQ: What types of systems can I connect this thermocouple voltage transmitter module to?\u003c\/h4\u003e\n\u003cp\u003eA: This module is designed to interface directly with any device that accepts a standard 0–5V or 0–10V analog input — including PLCs, data loggers, SCADA systems, Arduino and Raspberry Pi microcontrollers, industrial controllers, and custom data acquisition boards. Its compact 26mm × 23mm size makes it easy to integrate into tight enclosures.\u003c\/p\u003e\n\u003ch4\u003eQ: What is the temperature measurement range of this K-type transmitter module?\u003c\/h4\u003e\n\u003cp\u003eA: The module supports a wide measurement range of -100°C to +1100°C, making it suitable for both sub-zero environments and high-temperature industrial processes such as furnaces, kilns, and ovens when paired with an appropriate K-type thermocouple probe.\u003c\/p\u003e\n\u003ch4\u003eQ: How do I calculate the actual temperature from the output voltage?\u003c\/h4\u003e\n\u003cp\u003eA: Use the formula: \u003cem\u003e(Output Voltage ÷ Resolution) − 100 = Temperature in °C\u003c\/em\u003e. For the 0–5V mode, the resolution is 0.0041666 V\/°C. For the 0–10V mode, it is 0.0083333 V\/°C. For example, in 0–5V mode, a reading of 1.0V corresponds to (1.0 ÷ 0.0041666) − 100 = approximately 140°C.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the difference between the 0–5V and 0–10V output modes on this K-type temperature transmitter module?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The output mode is selected via the onboard J1 pad. With the pad in the open-circuit (default) state, the module outputs a 0.00V–5.00V analog signal. When the J1 pad is short-circuited, the output range switches to 0.00V–10.00V. Note that when using the 0–10V output range, your power supply voltage must be at least 15V DC to ensure accurate results.\"}}, {\"@type\": \"Question\", \"name\": \"What types of systems can I connect this thermocouple voltage transmitter module to?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"This module is designed to interface directly with any device that accepts a standard 0–5V or 0–10V analog input — including PLCs, data loggers, SCADA systems, Arduino and Raspberry Pi microcontrollers, industrial controllers, and custom data acquisition boards. Its compact 26mm × 23mm size makes it easy to integrate into tight enclosures.\"}}, {\"@type\": \"Question\", \"name\": \"What is the temperature measurement range of this K-type transmitter module?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The module supports a wide measurement range of -100°C to +1100°C, making it suitable for both sub-zero environments and high-temperature industrial processes such as furnaces, kilns, and ovens when paired with an appropriate K-type thermocouple probe.\"}}, {\"@type\": \"Question\", \"name\": \"How do I calculate the actual temperature from the output voltage?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Use the formula: (Output Voltage ÷ Resolution) − 100 = Temperature in °C. For the 0–5V mode, the resolution is 0.0041666 V\/°C. For the 0–10V mode, it is 0.0083333 V\/°C. For example, in 0–5V mode, a reading of 1.0V corresponds to (1.0 ÷ 0.0041666) − 100 = approximately 140°C.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Electronics \u0026 Tech\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/collections\/electronics-tech\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"K-Type Thermocouple Transmitter Module | 0-5V \u0026 0-10V Output\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/products\/k-type-thermocouple-temperature-transmitter-module-0-5v-0-10v\"}]}\u003c\/script\u003e","brand":"Vue","offers":[{"title":"None","offer_id":48743917519040,"sku":"200009209:350525","price":47.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0772\/9338\/7968\/files\/Sd7042cfc4aa74c57b6dcf03d1a8b2eb8I.webp?v=1786152000","url":"https:\/\/vueselect.com\/products\/k-type-thermocouple-temperature-transmitter-module-0-5v-0-10v","provider":"Vue","version":"1.0","type":"link"}