Embedded 5V 12V Dual Frequency RFID Card Reader Module Uart Wiegand Interface Vue 12V WG26 34

Dual Frequency RFID Reader Module | UART & Wiegand WG26/34

12V WG26 34
Sale price  $37.99 Regular price $45.99
Skip to product information
Embedded 5V 12V Dual Frequency RFID Card Reader Module Uart Wiegand Interface Vue 12V WG26 34

Dual Frequency RFID Reader Module | UART & Wiegand WG26/34

Sale price  $37.99 Regular price $45.99
Color

Dual Frequency Embedded RFID Card Reader Module

This compact embedded RFID card reader module supports both 125kHz and 13.56MHz (ISO 14443A) card frequencies, making it a versatile choice for access control systems, time-attendance terminals, and custom embedded projects. With dual UART and Wiegand (WG26/WG34) interface options, it integrates seamlessly into a wide range of controllers and microcontrollers. Its small footprint (47 × 26 × 5 mm) makes it ideal for flush-mounting or embedding into enclosures where space is at a premium. Made in Mainland China.

Key Features

  • Dual Frequency Support: Reads both 125kHz cards (EM4100) and 13.56MHz cards (ISO 14443A — Mifare S50, S70, MF 1K, DESFire, FM1208)
  • Flexible Interface: UART (TTL serial TX output) and Wiegand WG26/WG34 — switchable via a single wire connection
  • Read Range: EM4100 cards >8 cm; Mifare/13.56MHz cards >5 cm (varies by card coil and environment)
  • Built-in Indicator & Buzzer: Immediate audio and visual feedback on every successful card read
  • Wide Operating Temperature: -20°C to +70°C — suitable for indoor and mild outdoor environments
  • Low Power Draw: DC 12V supply, only 40mA current draw; a linear power supply is recommended for optimal read performance
  • Compact Form Factor: 47 × 26 × 5 mm — easy to embed into custom enclosures, panels, and housings

Technical Specifications

Parameter Value
Supply Voltage DC 12V
Current Consumption 40mA
Supported Card Frequencies 125kHz, 13.56MHz (ISO 14443A)
Supported Card Types EM4100, Mifare S50/S70/MF 1K, DESFire, FM1208
Interfaces UART (TTL), Wiegand WG26 / WG34
Read Distance (EM4100) >8 cm
Read Distance (13.56MHz) >5 cm
Operating Temperature -20°C to +70°C
Dimensions 47 × 26 × 5 mm
Indicator Yes (LED)
Buzzer Yes

Interface Wiring Guide

Wiegand Mode

  • VCC: DC 12V (linear power supply recommended)
  • GND: Ground
  • D1 / D0: Wiegand DATA1 / DATA0
  • FOR pin: Leave floating for WG26; connect to GND for WG34

UART Mode

  • VCC: DC 12V (linear power supply recommended)
  • GND: Ground
  • D0: TX (serial data output)

UART Output Data Format

The module outputs a structured serial packet over UART:

Data Header Length Card Type Card Number BCC Checksum Data End
0x02 0x09 0x01 SN0–SN3 XOR of all bytes except end 0x03

Example: A serial packet of 02 0A 02 2E 00 B6 D7 B5 F2 03 breaks down as: 0x02 = start byte; 0x0A = total 10-byte packet length; 0x02 = EM4100 card type; 2E 00 B6 D7 B5 = 5-byte card number; 0xF2 = BCC checksum (XOR of bytes 2–8); 0x03 = end byte.

Typical Applications

  • Access control panels and door entry systems
  • Time and attendance terminals
  • Industrial embedded identification systems
  • Smart locker and asset management systems
  • DIY Arduino / Raspberry Pi RFID projects

For technical background on RFID and contactless card standards, refer to the NIST Publications Library, which covers wireless and contactless technology standards used in identification systems.

Frequently Asked Questions

Q: What card types does this dual frequency RFID module support?

A: This module supports 125kHz cards including EM4100, as well as 13.56MHz ISO 14443A cards such as Mifare S50, S70, MF 1K, DESFire, and FM1208. The dual frequency capability means you can use it in systems that mix older 125kHz proximity cards with newer 13.56MHz smart cards.

Q: How do I switch between Wiegand WG26 and WG34 output modes?

A: Switching between WG26 and WG34 is done via the FOR pin. Leave the FOR pin floating (unconnected) for WG26 output. Connect the FOR pin to GND to switch to WG34 output. No firmware change is required.

Q: Can this RFID reader module work with a 5V power supply?

A: The module's primary rated voltage is DC 12V. While the product title mentions 5V and 12V compatibility, please verify your specific variant's power requirements before connecting. A linear (not switching) power supply is recommended for the best read performance and to minimize electrical noise.

Q: What is the maximum read range of this RFID module?

A: The maximum read distance for EM4100 (125kHz) cards is greater than 8 cm, and for 13.56MHz cards (Mifare/ISO 14443A) it is greater than 5 cm. Actual read range will vary depending on the card's coil size and the surrounding environment (e.g., metal surfaces nearby can reduce range).

Q: How is the UART data output formatted from this RFID card reader?

A: The UART output is a structured binary packet beginning with header byte 0x02, followed by total length, card type identifier, the card's serial number bytes (SN0–SN3), a BCC checksum (XOR of all bytes except the end byte), and ending with 0x03. This makes it straightforward to parse in any microcontroller or single-board computer environment.