{"product_id":"dc-8v-86v-battery-charge-discharge-controller-0-200-min-delay","title":"DC 8V–86V Battery Charge\/Discharge Controller | 0–200 Min Delay","description":"\n\u003ch2\u003eDC 8V–86V Battery Charge\/Discharge Controller with Adjustable Discharge Delay\u003c\/h2\u003e\n\u003cp\u003eTake full control of your battery system with this versatile DC 8V–86V Battery Charge\/Discharge Controller. Designed for lithium and lead-acid battery setups, this compact module automatically manages start and stop discharge voltages with precision, helping safeguard your battery bank from overvoltage and undervoltage conditions. With a programmable discharge delay of 0–200 minutes and a clear digital display, it's the ideal solution for solar energy systems, DIY power banks, electric vehicles, backup power systems, and more.\u003c\/p\u003e\n\n\u003cp\u003eMade in Mainland China.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Works with any DC 8V–86V battery, including lithium and lead-acid types, up to 30A load current.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Discharge Voltage:\u003c\/strong\u003e Freely set your own start and stop discharge voltage thresholds with 0.1V control accuracy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProgrammable Discharge Delay:\u003c\/strong\u003e Set a discharge delay anywhere from 0 to 200 minutes to fine-tune your system's behavior.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReal-Time Digital Display:\u003c\/strong\u003e Monitor live battery voltage at a glance; display accuracy of 0.1V keeps you informed at all times.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Separate LED indicators for start, stop, and delay status make operation intuitive and straightforward.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelay-Controlled Output:\u003c\/strong\u003e Active direct output via relay ensures reliable switching with ±0.1V voltage accuracy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Form Factor:\u003c\/strong\u003e Measures just 90 × 62 × 30 mm — easy to integrate into any enclosure or panel.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimple Programming Interface:\u003c\/strong\u003e Set and save your parameters using the Set, Up, and Down buttons — no special tools needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDC 8V – 86V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDC 8V – 86V (corresponds to input)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eLoad Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e8V–86V \/ 30A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDischarge Delay Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0 – 200 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDisplay Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eVoltage Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e±0.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eActive Direct Output (Relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e90 × 62 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e8V–86V Lithium \u0026amp; Lead-Acid Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMainland China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHow to Program Your Controller\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eView Settings:\u003c\/strong\u003e In normal mode, press the Set key to view discharge delay time; press Up to display start voltage; press Down to display stop voltage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnter Setting Mode:\u003c\/strong\u003e Hold the Set key for 3 seconds to enter programming mode.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjust Start Voltage:\u003c\/strong\u003e When the discharge indicator blinks, use Up\/Down keys to set your desired start discharge voltage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjust Stop Voltage:\u003c\/strong\u003e Short-press Set to switch to stop voltage; adjust with Up\/Down keys while the stop indicator blinks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSet Discharge Delay:\u003c\/strong\u003e Short-press Set again; when both discharge and stop indicators blink, use Up\/Down to set the delay time (0–200 min).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSave \u0026amp; Exit:\u003c\/strong\u003e Hold the Set key for 3 seconds to save all settings and return to normal operating mode.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cem\u003eTip: Always set your stop discharge voltage before setting your start discharge voltage, and ensure the start voltage value is always higher than the stop voltage value.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1× DC 8V–86V Battery Charge\/Discharge Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHelpful Resource\u003c\/h3\u003e\n\u003cp\u003eFor a deeper understanding of battery management systems and electrical safety standards, visit the U.S. Consumer Product Safety Commission (CPSC) Battery Safety Resource.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: What types of batteries are compatible with this charge\/discharge controller?\u003c\/h4\u003e\n\u003cp\u003eA: This controller is compatible with any DC 8V–86V battery, including lithium-ion and lead-acid battery systems. It can handle load currents up to 30A, making it suitable for a wide range of applications such as solar setups, DIY power banks, electric scooters, and backup power systems.\u003c\/p\u003e\n\n\u003ch4\u003eQ: How does the discharge delay feature work?\u003c\/h4\u003e\n\u003cp\u003eA: The discharge delay (0–200 minutes) adds a timed buffer after the battery voltage drops to the set stop threshold. During this delay period, both the discharge and stop LED indicators will blink, and the battery continues to discharge. Once the delay time elapses, the relay disconnects and stops the output — ideal for avoiding nuisance shutdowns caused by momentary voltage dips.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What should I do if the controller won't let me set the start discharge voltage?\u003c\/h4\u003e\n\u003cp\u003eA: Make sure you set the stop discharge voltage first, then set the start discharge voltage. The controller requires that the start voltage always be higher than the stop voltage. If you try to set them in the wrong order or assign equal values, the controller will not accept the configuration.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Why does my system start and stop frequently (hunting)?\u003c\/h4\u003e\n\u003cp\u003eA: Frequent cycling is usually caused by a very small difference between your start and stop discharge voltage settings. Increase the gap between the two values to create a wider hysteresis band and prevent rapid on\/off switching.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What does the digital display show during normal operation?\u003c\/h4\u003e\n\u003cp\u003eA: During normal operation, the display shows the real-time battery voltage with 0.1V accuracy. You can press the Set, Up, or Down keys briefly to check your programmed start voltage, stop voltage, or delay time without entering setting mode.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What types of batteries are compatible with this charge\/discharge controller?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"This controller is compatible with any DC 8V–86V battery, including lithium-ion and lead-acid battery systems. It can handle load currents up to 30A, making it suitable for a wide range of applications such as solar setups, DIY power banks, electric scooters, and backup power systems.\"}}, {\"@type\": \"Question\", \"name\": \"How does the discharge delay feature work?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The discharge delay (0–200 minutes) adds a timed buffer after the battery voltage drops to the set stop threshold. During this delay period, both the discharge and stop LED indicators will blink, and the battery continues to discharge. Once the delay time elapses, the relay disconnects and stops the output — ideal for avoiding nuisance shutdowns caused by momentary voltage dips.\"}}, {\"@type\": \"Question\", \"name\": \"What should I do if the controller won't let me set the start discharge voltage?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Make sure you set the stop discharge voltage first, then set the start discharge voltage. The controller requires that the start voltage always be higher than the stop voltage. If you try to set them in the wrong order or assign equal values, the controller will not accept the configuration.\"}}, {\"@type\": \"Question\", \"name\": \"Why does my system start and stop frequently (hunting)?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Frequent cycling is usually caused by a very small difference between your start and stop discharge voltage settings. Increase the gap between the two values to create a wider hysteresis band and prevent rapid on\/off switching.\"}}, {\"@type\": \"Question\", \"name\": \"What does the digital display show during normal operation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"During normal operation, the display shows the real-time battery voltage with 0.1V accuracy. You can press the Set, Up, or Down keys briefly to check your programmed start voltage, stop voltage, or delay time without entering setting mode.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Fasteners \u0026 Electrical\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/collections\/fasteners-electrical\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"DC 8V–86V Battery Charge\/Discharge Controller | 0–200 Min Delay\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/products\/dc-8v-86v-battery-charge-discharge-controller-0-200-min-delay\"}]}\u003c\/script\u003e","brand":"Vue","offers":[{"title":"Default Title","offer_id":48748623003840,"sku":"\u003cnone\u003e","price":66.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0772\/9338\/7968\/files\/S444f8a68efc1486daf92314bcc5928f4r.webp?v=1786204819","url":"https:\/\/vueselect.com\/products\/dc-8v-86v-battery-charge-discharge-controller-0-200-min-delay","provider":"Vue","version":"1.0","type":"link"}