DC 8V-86V Battery Charge/Discharge Controller 0-200 Min Discharge Delay Lithium Battery Protection Lead-Acid Battery Controller Vue Default Title

DC 8V–86V Battery Charge/Discharge Controller | 0–200 Min Delay

Default Title
Sale price  $66.99 Regular price $81.99
Skip to product information
DC 8V-86V Battery Charge/Discharge Controller 0-200 Min Discharge Delay Lithium Battery Protection Lead-Acid Battery Controller Vue Default Title

DC 8V–86V Battery Charge/Discharge Controller | 0–200 Min Delay

Sale price  $66.99 Regular price $81.99
Default TitleDefault Title

DC 8V–86V Battery Charge/Discharge Controller with Adjustable Discharge Delay

Take full control of your battery system with this versatile DC 8V–86V Battery Charge/Discharge Controller. Designed for lithium and lead-acid battery setups, this compact module automatically manages start and stop discharge voltages with precision, helping safeguard your battery bank from overvoltage and undervoltage conditions. With a programmable discharge delay of 0–200 minutes and a clear digital display, it's the ideal solution for solar energy systems, DIY power banks, electric vehicles, backup power systems, and more.

Made in Mainland China.

Key Features

  • Wide Voltage Compatibility: Works with any DC 8V–86V battery, including lithium and lead-acid types, up to 30A load current.
  • Adjustable Discharge Voltage: Freely set your own start and stop discharge voltage thresholds with 0.1V control accuracy.
  • Programmable Discharge Delay: Set a discharge delay anywhere from 0 to 200 minutes to fine-tune your system's behavior.
  • Real-Time Digital Display: Monitor live battery voltage at a glance; display accuracy of 0.1V keeps you informed at all times.
  • LED Indicators: Separate LED indicators for start, stop, and delay status make operation intuitive and straightforward.
  • Relay-Controlled Output: Active direct output via relay ensures reliable switching with ±0.1V voltage accuracy.
  • Compact Form Factor: Measures just 90 × 62 × 30 mm — easy to integrate into any enclosure or panel.
  • Simple Programming Interface: Set and save your parameters using the Set, Up, and Down buttons — no special tools needed.

Technical Specifications

Input Voltage DC 8V – 86V
Output Voltage DC 8V – 86V (corresponds to input)
Load Power 8V–86V / 30A
Discharge Delay Time 0 – 200 Minutes
Display Accuracy 0.1V
Control Accuracy 0.1V
Voltage Error ±0.1V
Output Type Active Direct Output (Relay)
Product Size 90 × 62 × 30 mm
Application 8V–86V Lithium & Lead-Acid Batteries
Country of Origin Mainland China

How to Program Your Controller

  1. View Settings: In normal mode, press the Set key to view discharge delay time; press Up to display start voltage; press Down to display stop voltage.
  2. Enter Setting Mode: Hold the Set key for 3 seconds to enter programming mode.
  3. Adjust Start Voltage: When the discharge indicator blinks, use Up/Down keys to set your desired start discharge voltage.
  4. Adjust Stop Voltage: Short-press Set to switch to stop voltage; adjust with Up/Down keys while the stop indicator blinks.
  5. Set Discharge Delay: Short-press Set again; when both discharge and stop indicators blink, use Up/Down to set the delay time (0–200 min).
  6. Save & Exit: Hold the Set key for 3 seconds to save all settings and return to normal operating mode.

Tip: Always set your stop discharge voltage before setting your start discharge voltage, and ensure the start voltage value is always higher than the stop voltage value.

What's in the Box

  • 1× DC 8V–86V Battery Charge/Discharge Controller

Helpful Resource

For a deeper understanding of battery management systems and electrical safety standards, visit the U.S. Consumer Product Safety Commission (CPSC) Battery Safety Resource.

Frequently Asked Questions

Q: What types of batteries are compatible with this charge/discharge controller?

A: This controller is compatible with any DC 8V–86V battery, including lithium-ion and lead-acid battery systems. It can handle load currents up to 30A, making it suitable for a wide range of applications such as solar setups, DIY power banks, electric scooters, and backup power systems.

Q: How does the discharge delay feature work?

A: The discharge delay (0–200 minutes) adds a timed buffer after the battery voltage drops to the set stop threshold. During this delay period, both the discharge and stop LED indicators will blink, and the battery continues to discharge. Once the delay time elapses, the relay disconnects and stops the output — ideal for avoiding nuisance shutdowns caused by momentary voltage dips.

Q: What should I do if the controller won't let me set the start discharge voltage?

A: Make sure you set the stop discharge voltage first, then set the start discharge voltage. The controller requires that the start voltage always be higher than the stop voltage. If you try to set them in the wrong order or assign equal values, the controller will not accept the configuration.

Q: Why does my system start and stop frequently (hunting)?

A: Frequent cycling is usually caused by a very small difference between your start and stop discharge voltage settings. Increase the gap between the two values to create a wider hysteresis band and prevent rapid on/off switching.

Q: What does the digital display show during normal operation?

A: During normal operation, the display shows the real-time battery voltage with 0.1V accuracy. You can press the Set, Up, or Down keys briefly to check your programmed start voltage, stop voltage, or delay time without entering setting mode.