{"product_id":"dc-6-30v-programmable-time-delay-relay-module-lcd-display","title":"DC 6-30V Programmable Time Delay Relay Module with LCD","description":"\n\u003ch2\u003eDC 6-30V Programmable Time Delay Relay Module with LCD Digital Display\u003c\/h2\u003e\n\u003cp\u003eTake precise control of your electrical circuits with this industrial-grade programmable time delay relay module. Featuring a clear two-line LCD display, 10 flexible working modes (P0–P9), and a wide input voltage range of 6V to 30V DC, this module is the ideal solution for automation projects, DIY electronics, and professional control systems. Made in China.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-line LCD Display:\u003c\/strong\u003e View timing parameters at a glance — no guesswork, no extra equipment needed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMultiple Trigger Modes:\u003c\/strong\u003e Supports high-level (3.0V–24.0V), low-level (0.0V–0.2V), and switch-quantity triggering to suit virtually any circuit setup.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUART Parameter Modification:\u003c\/strong\u003e Adjust settings remotely via UART communication for added flexibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEmergency Stop Button:\u003c\/strong\u003e Instantly halt timing operations for safe and responsive control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow-Power Sleep Mode:\u003c\/strong\u003e Automatically enters low-power state after 5 minutes of inactivity; any action wakes it up immediately.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndividual Parameter Control:\u003c\/strong\u003e OP (on-time), CL (off-time), and LOP (cycle count) can each be set independently.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-Volatile Memory:\u003c\/strong\u003e All parameters are automatically saved on power-off — your settings are retained every time.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptocoupler Isolation:\u003c\/strong\u003e Strong anti-interference capability, making it suitable for industrial-grade environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Service Life:\u003c\/strong\u003e Over 100,000 switching operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003eDC 6V – 30V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eTrigger Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003eHigh: 3.0V–24.0V \/ Low: 0.0V–0.2V \/ Switch Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eStatic Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e15mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eOperating Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e50mA (XY-WJ01, XY-WM01) \/ 50mA–130mA (XY-DJ01)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eMax Output Load — XY-WJ01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003eDC 30V 10A \/ AC 220V 5A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eMax Output Load — XY-WM01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003eDC 30V 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eMax Output Load — XY-DJ01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003eDC 30V 30A \/ AC 220V 30A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eTiming Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e0.01 sec – 9,999 min\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eWorking Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eService Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e100,000+ operations\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDimensions — XY-WJ01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e7.1 × 3.9 × 2.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDimensions — XY-WM01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e7.9 × 3.8 × 4.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDimensions — XY-DJ01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e9.8 × 5.5 × 4.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px; border:1px solid #ddd;\"\u003eMade in China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWorking Modes (P0–P9)\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP0:\u003c\/strong\u003e Trigger → MOS conducts for OP time, then disconnects. Further signals during OP time are ignored.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP1:\u003c\/strong\u003e Trigger → MOS conducts for OP time; re-triggering during OP starts a new timer.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP2:\u003c\/strong\u003e Trigger → MOS conducts for OP time; re-triggering resets the timer and immediately disconnects MOS.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP3:\u003c\/strong\u003e Trigger → MOS disconnects for CL time, then reconnects.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP4:\u003c\/strong\u003e Trigger → MOS conducts for OP time, disconnects for CL time, loops. Signal during loop stops cycle; end state is MOS disconnected.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP5:\u003c\/strong\u003e Trigger → MOS disconnects for CL time, conducts for OP time, loops. Signal during loop stops cycle; end state is MOS conducting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP6:\u003c\/strong\u003e Auto-start on power-on. MOS conducts for OP time, disconnects for CL time, loops. Signal is inactive during loop; end state is MOS disconnected.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP7:\u003c\/strong\u003e Auto-start on power-on. MOS disconnects for CL time, conducts for OP time, loops. Signal is inactive during loop; end state is MOS conducting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP8:\u003c\/strong\u003e Signal hold: MOS conducts while signal is active; disconnects after OP time once signal drops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP9:\u003c\/strong\u003e Signal hold: MOS disconnects while signal is active; conducts after CL time once signal drops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTiming Range Selector\u003c\/h3\u003e\n\u003cp\u003eWithin the OP\/CL parameter interface, press the STOP button to select the active timing unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eXXXX\u003c\/strong\u003e → 1 sec – 9,999 sec\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eXXX.X\u003c\/strong\u003e → 0.1 sec – 999.9 sec\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eXX.XX\u003c\/strong\u003e → 0.01 sec – 99.99 sec\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eX.X.X.X\u003c\/strong\u003e → 1 min – 999.9 min\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow to Configure Parameters\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003ePress and hold the \u003cstrong\u003eSET\u003c\/strong\u003e key to enter the setting interface.\u003c\/li\u003e\n  \u003cli\u003eSelect the working mode using \u003cstrong\u003eUP\/DOWN\u003c\/strong\u003e keys (flashing mode indicator confirms selection).\u003c\/li\u003e\n  \u003cli\u003eShort-press \u003cstrong\u003eSET\u003c\/strong\u003e to confirm mode and enter system parameter settings.\u003c\/li\u003e\n  \u003cli\u003ePress \u003cstrong\u003eSET\u003c\/strong\u003e to cycle between parameters; short\/long press \u003cstrong\u003eUP\/DOWN\u003c\/strong\u003e to adjust values.\u003c\/li\u003e\n  \u003cli\u003eIn the OP\/CL interface, short-press \u003cstrong\u003eSTOP\u003c\/strong\u003e to switch the timing unit (1s \/ 0.1s \/ 0.01s \/ 1min).\u003c\/li\u003e\n  \u003cli\u003eHold \u003cstrong\u003eSET\u003c\/strong\u003e for 2+ seconds to save all settings and exit the menu.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1× Relay Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cem\u003eNote: Colors may vary slightly due to lighting and screen calibration. Please allow ±1–3 cm tolerance due to manual measurement.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor guidance on electrical safety standards for low-voltage equipment, visit the U.S. Consumer Product Safety Commission — Electrical Safety Resource Center.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: What voltage range does this programmable time delay relay module support?\u003c\/h4\u003e\n\u003cp\u003eA: This relay module operates on a wide DC input range of 6V to 30V, making it compatible with a broad variety of power supplies and automation systems.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Can I save my timer settings if there is a power outage?\u003c\/h4\u003e\n\u003cp\u003eA: Yes — all configured parameters (OP time, CL time, LOP cycles, and working mode) are automatically saved to non-volatile memory and will be restored the next time the module powers on.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What is the difference between the XY-WJ01, XY-WM01, and XY-DJ01 variants?\u003c\/h4\u003e\n\u003cp\u003eA: The variants differ in maximum output load capacity and physical size. The XY-WJ01 supports DC 30V\/10A and AC 220V\/5A; the XY-WM01 is DC-only at DC 30V\/10A; the XY-DJ01 is the heavy-duty version, supporting DC 30V\/30A and AC 220V\/30A — ideal for higher-current applications.\u003c\/p\u003e\n\n\u003ch4\u003eQ: How many working modes does this relay timer module offer?\u003c\/h4\u003e\n\u003cp\u003eA: The module features 10 programmable working modes (P0 through P9), covering single-shot triggering, retriggerable timing, cyclic looping with adjustable on\/off times, signal-hold modes, and auto-start-on-power-up sequences.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What timing precision and range can I achieve with this module?\u003c\/h4\u003e\n\u003cp\u003eA: The timing range spans from 0.01 seconds all the way to 9,999 minutes. You can select from four precision levels (0.01s, 0.1s, 1s, and 1min units) directly from the OP\/CL parameter interface using the STOP button.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What voltage range does this programmable time delay relay module support?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"This relay module operates on a wide DC input range of 6V to 30V, making it compatible with a broad variety of power supplies and automation systems.\"}}, {\"@type\": \"Question\", \"name\": \"Can I save my timer settings if there is a power outage?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes — all configured parameters (OP time, CL time, LOP cycles, and working mode) are automatically saved to non-volatile memory and will be restored the next time the module powers on.\"}}, {\"@type\": \"Question\", \"name\": \"What is the difference between the XY-WJ01, XY-WM01, and XY-DJ01 variants?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The variants differ in maximum output load capacity and physical size. The XY-WJ01 supports DC 30V\/10A and AC 220V\/5A; the XY-WM01 is DC-only at DC 30V\/10A; the XY-DJ01 is the heavy-duty version, supporting DC 30V\/30A and AC 220V\/30A — ideal for higher-current applications.\"}}, {\"@type\": \"Question\", \"name\": \"How many working modes does this relay timer module offer?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The module features 10 programmable working modes (P0 through P9), covering single-shot triggering, retriggerable timing, cyclic looping with adjustable on\/off times, signal-hold modes, and auto-start-on-power-up sequences.\"}}, {\"@type\": \"Question\", \"name\": \"What timing precision and range can I achieve with this module?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The timing range spans from 0.01 seconds all the way to 9,999 minutes. You can select from four precision levels (0.01s, 0.1s, 1s, and 1min units) directly from the OP\/CL parameter interface using the STOP button.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Fasteners \u0026 Electrical\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/collections\/fasteners-electrical\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"DC 6-30V Programmable Time Delay Relay Module with LCD\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/products\/dc-6-30v-programmable-time-delay-relay-module-lcd-display\"}]}\u003c\/script\u003e","brand":"Vue","offers":[{"title":"XY-DJ01","offer_id":48746928570560,"sku":"5:200004182#XY-DJ01","price":62.99,"currency_code":"USD","in_stock":true},{"title":"XY-WJ01","offer_id":48746928603328,"sku":"5:144170022#XY-WJ01","price":62.99,"currency_code":"USD","in_stock":true},{"title":"XY-WM01","offer_id":48746928636096,"sku":"5:200004763#XY-WM01","price":62.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0772\/9338\/7968\/files\/S51bc9841c93242ee83a486b042de4bc0x.webp?v=1786196040","url":"https:\/\/vueselect.com\/products\/dc-6-30v-programmable-time-delay-relay-module-lcd-display","provider":"Vue","version":"1.0","type":"link"}