{"product_id":"concealed-shear-electromagnetic-lock-door-access-control-dc-12v-24v","title":"Concealed Shear Electromagnetic Lock DC 12V\/24V | Access Control","description":"\n\u003ch2\u003eAsia-Teco Concealed Shear Electromagnetic Lock for Door Access Control Systems\u003c\/h2\u003e\n\u003cp\u003eUpgrade your building's security with the \u003cstrong\u003eAsia-Teco Concealed Shear Electromagnetic Lock (Model 1200SL\/1300L)\u003c\/strong\u003e — a high-performance embedded electric locking solution engineered for modern access control systems. By combining electromagnetic holding force with mechanical shear force, this lock delivers exceptional door security for offices, commercial buildings, server rooms, and any environment where reliable, fast-acting access control is essential.\u003c\/p\u003e\n\u003cp\u003eMade in Mainland China.\u003c\/p\u003e\n\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003cp\u003eWhen power is applied, the built-in electromagnet generates a strong magnetic field, drawing the iron plate into alignment and driving the lock tongue into the lock-tongue hole — securing the door firmly. This dual-action mechanism (electromagnetic + mechanical shear) means the door holds securely even under significant lateral force. When the circuit is interrupted or the access control system grants entry, the lock releases instantly.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Force Locking:\u003c\/strong\u003e Combines electromagnetic attraction and mechanical shear force for outstanding holding strength that resists forced entry.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConcealed \/ Embedded Installation:\u003c\/strong\u003e Installs neatly inside the door frame or door leaf, preserving clean aesthetics — no exposed hardware.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Voltage Input:\u003c\/strong\u003e Operates on DC 12V or DC 24V power, making it easy to integrate into most existing access control power supplies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Time Delay:\u003c\/strong\u003e Four selectable delay settings — 0 \/ 3 \/ 6 \/ 9 seconds — let you fine-tune door-locking behavior to match your workflow.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Feedback Signals (NC \u0026amp; NO):\u003c\/strong\u003e Provides both Normally Closed and Normally Open dry-contact feedback signals for seamless integration with access control panels, alarm systems, or building management systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNo Mechanical Wear:\u003c\/strong\u003e Relies primarily on magnetic force rather than moving parts, resulting in a longer service life and lower maintenance demands.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRapid Lock \/ Unlock Response:\u003c\/strong\u003e Locks and unlocks in milliseconds — ideal for high-traffic entry points and time-sensitive security scenarios.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Temperature Range:\u003c\/strong\u003e Rated for operation from -40°C to +55°C, suitable for indoor and protected outdoor environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHorizontal or Vertical Mounting:\u003c\/strong\u003e Install in either orientation to suit your door type and frame configuration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFire \u0026amp; Emergency Safe:\u003c\/strong\u003e Integrates with fire alarm systems to automatically release during emergencies, ensuring safe egress at all times.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"padding:8px; border:1px solid #ddd; text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:8px; border:1px solid #ddd; text-align:left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e1200SL \/ 1300L\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDC 12V – DC 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWorking Current (DC 12V)\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eStarting: 1.6A | Maintaining: 0.22A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWorking Current (DC 24V)\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eStarting: 1.0A | Maintaining: 0.13A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eFeedback Signal\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eNC \u0026amp; NO dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAdsorption Spacing\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWithin 4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDelay Settings\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0 \/ 3 \/ 6 \/ 9 seconds (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e-40°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eInstallation Method\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDrilling \/ embedded\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eHorizontal or Vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eHigh-Concern Chemicals\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMainland China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Maintenance Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProfessional installation is recommended. Ensure proper alignment between the lock body and the iron plate for full contact.\u003c\/li\u003e\n  \u003cli\u003eAdjust the iron plate so the gap between the lock and plate is \u003cstrong\u003e3–4 mm\u003c\/strong\u003e (minimum 2 mm). Tighten all fastening screws after adjustment.\u003c\/li\u003e\n  \u003cli\u003eAfter installation, test by powering on — a successful lock engagement is silent. A \"click\" sound indicates the gap needs slight reduction.\u003c\/li\u003e\n  \u003cli\u003eIntegrate with a UPS (uninterruptible power supply) or backup power source to maintain security during power outages.\u003c\/li\u003e\n  \u003cli\u003eRegularly inspect the electromagnet, clean the lock body, and clear any dust or debris from the installation area to maintain consistent performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSafety \u0026amp; Standards\u003c\/h3\u003e\n\u003cp\u003eFor guidance on electrical safety in access control installations, refer to the \u003ca href=\"https:\/\/www.osha.gov\/electrical\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOSHA Electrical Safety guidelines\u003c\/a\u003e. Ensuring correct wiring practices protects both personnel and equipment during installation and ongoing operation.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: What voltage does the Asia-Teco concealed shear electromagnetic lock require?\u003c\/h4\u003e\n\u003cp\u003eA: The lock is compatible with both DC 12V and DC 24V power supplies. At DC 12V, the starting current is 1.6A with a maintaining current of 0.22A. At DC 24V, the starting current is 1.0A with a maintaining current of 0.13A, making it easy to match to most standard access control power supplies.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Can this shear lock be integrated with a fire alarm system for emergency release?\u003c\/h4\u003e\n\u003cp\u003eA: Yes. The Asia-Teco shear lock is designed to integrate with fire alarm and building management systems. When a fire alarm is triggered, the system can automatically cut power to the lock, releasing the door immediately to ensure safe evacuation — a critical safety feature for commercial and public buildings.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What is the purpose of the adjustable time delay function?\u003c\/h4\u003e\n\u003cp\u003eA: The 0\/3\/6\/9-second adjustable delay allows you to configure how long after an access event the door remains unlocked before the lock re-engages. This is useful in high-traffic scenarios — giving individuals enough time to pass through without the door re-locking prematurely.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Is professional installation required for this electromagnetic shear lock?\u003c\/h4\u003e\n\u003cp\u003eA: Professional installation is strongly recommended. The lock must be precisely aligned within the door frame via a drilled recess, and the iron plate gap must be calibrated to 3–4 mm. Incorrect installation can result in inconsistent locking or failure to release. A qualified technician can also ensure proper integration with your power supply and access control panel.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What makes a shear lock different from a standard electromagnetic (surface-mount) lock?\u003c\/h4\u003e\n\u003cp\u003eA: A standard surface-mount electromagnetic lock holds the door using magnetic attraction force alone and is visible on the door frame. A shear lock is embedded (concealed) within the door and frame, and adds mechanical shear force in addition to electromagnetic force — significantly increasing resistance to lateral stress and forced entry attempts, while maintaining a cleaner aesthetic.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What voltage does the Asia-Teco concealed shear electromagnetic lock require?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The lock is compatible with both DC 12V and DC 24V power supplies. At DC 12V, the starting current is 1.6A with a maintaining current of 0.22A. At DC 24V, the starting current is 1.0A with a maintaining current of 0.13A, making it easy to match to most standard access control power supplies.\"}}, {\"@type\": \"Question\", \"name\": \"Can this shear lock be integrated with a fire alarm system for emergency release?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The Asia-Teco shear lock is designed to integrate with fire alarm and building management systems. When a fire alarm is triggered, the system can automatically cut power to the lock, releasing the door immediately to ensure safe evacuation — a critical safety feature for commercial and public buildings.\"}}, {\"@type\": \"Question\", \"name\": \"What is the purpose of the adjustable time delay function?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The 0\/3\/6\/9-second adjustable delay allows you to configure how long after an access event the door remains unlocked before the lock re-engages. This is useful in high-traffic scenarios — giving individuals enough time to pass through without the door re-locking prematurely.\"}}, {\"@type\": \"Question\", \"name\": \"Is professional installation required for this electromagnetic shear lock?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Professional installation is strongly recommended. The lock must be precisely aligned within the door frame via a drilled recess, and the iron plate gap must be calibrated to 3–4 mm. Incorrect installation can result in inconsistent locking or failure to release. A qualified technician can also ensure proper integration with your power supply and access control panel.\"}}, {\"@type\": \"Question\", \"name\": \"What makes a shear lock different from a standard electromagnetic (surface-mount) lock?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A standard surface-mount electromagnetic lock holds the door using magnetic attraction force alone and is visible on the door frame. A shear lock is embedded (concealed) within the door and frame, and adds mechanical shear force in addition to electromagnetic force — significantly increasing resistance to lateral stress and forced entry attempts, while maintaining a cleaner aesthetic.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Fasteners \u0026 Electrical\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/collections\/fasteners-electrical\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"Concealed Shear Electromagnetic Lock DC 12V\/24V | Access Control\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/products\/concealed-shear-electromagnetic-lock-door-access-control-dc-12v-24v\"}]}\u003c\/script\u003e","brand":"Vue","offers":[{"title":"model B FBD-1300SL","offer_id":48750478590144,"sku":"14:350850#model B FBD-1300SL","price":211.99,"currency_code":"USD","in_stock":true},{"title":"model A FBD-1200SL","offer_id":48750478622912,"sku":"14:29#model A FBD-1200SL","price":211.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0772\/9338\/7968\/files\/S59f7cea09d91487ca089d356fcf008351.webp?v=1786228046","url":"https:\/\/vueselect.com\/products\/concealed-shear-electromagnetic-lock-door-access-control-dc-12v-24v","provider":"Vue","version":"1.0","type":"link"}