6A Adjustable Time Delay Relay Module – 38 Modes, Dual Output
6A Adjustable Time Delay Relay Module – Dual Output, LED Digital Timer
Take precise control of your electrical circuits with this versatile 6A Adjustable Time Delay Relay Module. Featuring dual relay outputs, a bright LED digital display, and support for a wide input voltage range (DC 5V/7–30V or AC 110–220V), this module is an excellent solution for automation projects, industrial controls, DIY electronics, and timed switching applications. With an extraordinary 38 programmable operating modes and a timing range from 0.01 seconds to 999 minutes, you get unmatched flexibility in a compact, easy-to-wire package.
Made in Mainland China.
Key Specifications
- Input Voltage: DC 5V / 7–30V or AC 110–220V
- Output Load: DC or AC loads up to 6A
- Timing Range: 0.01 seconds to 999 minutes
- Relay Channels: 2-way (dual output)
- Display: LED digital readout
- Dimensions: 87mm × 47mm
- Programmable Modes: 38 modes (P-11 through P-48)
38 Programmable Operating Modes
This relay module offers an extensive library of trigger and timing logic modes, organized in four groups:
Group 1 — Signal-Triggered Momentary & Latch Modes (P-11 to P-18)
- P-11: Point mode — relay closes with signal, opens when signal is lost.
- P-12: Self-locking — first signal closes relay; second signal opens it.
- P-13: Timed output A seconds after signal; retrigger during delay is ignored.
- P-14: Timed output A seconds; retrigger resets the timer.
- P-15: Timed output A seconds; retrigger adds to (overlays) the timer.
- P-16: Timed output A seconds; retrigger resets output immediately.
- P-17: Signal closes relay; on signal loss, times A seconds then opens. Retrigger during delay maintains output.
- P-18: On power-up relay closes immediately, then opens after A seconds.
Group 2 — Delayed-Close Modes (P-21 to P-28)
- P-21: Signal given → relay closes after A-second delay.
- P-22: Signal held > A seconds → relay closes; signal loss opens it.
- P-23: Signal absent > A seconds → relay closes; signal returns, relay opens.
- P-24: Signal > A seconds to close; signal absent > A seconds to open.
- P-25: Signal > A seconds to close; signal > A seconds to open.
- P-26: Relay closes for A seconds with signal, then closes again for A seconds when signal is lost.
- P-27: Detects pulse signal to close; no pulse → relay delays A seconds then closes.
- P-28: On power-up, delays A seconds then relay closes until power is removed.
Group 3 — Cyclic / Pulse Loop Modes (P-31 to P-38)
- P-31: On power-up: relay on for A seconds, off for B seconds — infinite cycle.
- P-32: Signal starts P-31 cycle; signal loss ends cycle.
- P-33: First signal starts P-31 cycle; second signal ends cycle.
- P-34: On power-up, after A-second delay relay closes, then opens after B seconds.
- P-35: Signal given → after A-second delay relay closes, opens after B seconds.
- P-36: Signal held > A seconds → relay closes for B seconds; signal loss stops timing.
- P-37: Signal closes relay for A seconds, then off for B seconds; retrigger blocked during A+B window.
- P-38: Signal closes relay for A seconds, then off for B seconds — repeated automatically.
Group 4 — Signal-Loss & Dual-Relay Modes (P-41 to P-48)
- P-41: Signal loss triggers relay; relay opens after delay A.
- P-42: Signal disappears → relay works after A delay; stops after work period.
- P-43: Signal absent > A seconds → relay closes for B seconds.
- P-44: After A signal pulses → relay closes for B seconds.
- P-45: On power-up: Relay 1 on for A seconds; Relay 2 on for B seconds.
- P-46: Signal 1 → Relay 1 on for A seconds; Relay 2 on for B seconds.
- P-47: Signal 1 → Relay 1 on for A seconds; then Relay 2 starts for B seconds; both disconnect simultaneously.
- P-48: On power-up: Relay 1 cycles A on / B off; Relay 2 cycles C on / D off — continuous loop.
Who Is This Module For?
- Electronics hobbyists and makers building automation circuits
- Industrial control and PLC supplementary timing applications
- Home automation and smart switching projects
- Agricultural and irrigation timed control systems
- Lighting, motor, and pump time-control installations
Package Contents
- 1× 6A Adjustable Time Delay Relay Module
Notes
- Colors may appear slightly different due to monitor settings and lighting.
- Please allow ±1–3 cm variance due to manual measurement.
For more information on electrical safety standards for low-voltage equipment, visit the U.S. Consumer Product Safety Commission – Electrical Safety.
Frequently Asked Questions
Q: What voltage inputs does this time delay relay module support?
A: This adjustable time delay relay module supports both DC input (5V, or 7–30V) and AC input (110–220V), making it compatible with a wide range of power sources for home, workshop, and industrial use.
Q: How many timing modes does the digital relay module have?
A: The module offers 38 programmable operating modes (P-11 through P-48), covering point triggering, self-locking, pulse cycling, delay-on, delay-off, dual-relay sequential control, and more — giving you fine-grained control over any switching application.
Q: What is the maximum load this relay module can handle?
A: The relay module is rated for up to 6A on both DC and AC loads, suitable for controlling lights, small motors, pumps, solenoids, and other moderate-power devices.
Q: What is the timing range available on this module?
A: The timing range is highly flexible — from as short as 0.01 seconds up to 999 minutes, allowing you to tailor the relay timing precisely to your automation or control project requirements.