{"product_id":"3-phase-bidirectional-smart-kwh-energy-meter-rs485","title":"3-Phase Bidirectional Smart kWh Energy Meter | RS485","description":"\n\u003ch2\u003e3-Phase Multifunction Smart Bidirectional Energy Power kWh Meter with RS485 Communication\u003c\/h2\u003e\n\u003cp\u003eTake complete control of your three-phase electrical monitoring with this advanced Smart Bidirectional Energy Meter. Built on cutting-edge microelectronic technology and large-scale integrated circuits, this DIN rail-mounted meter uses digital sampling processing and SMT technology to deliver precise, real-time measurement of AC active and reactive energy across all three phases. Whether you're managing commercial electrical systems, industrial facilities, or solar installations, this meter gives you the data you need — bidirectional energy flow included.\u003c\/p\u003e\n\n\u003cp\u003eMade in Mainland China.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBidirectional Energy Monitoring:\u003c\/strong\u003e Measures both import and export active energy, making it ideal for solar\/renewable energy setups and smart grid applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLCD Backlight Display:\u003c\/strong\u003e Clearly readable screen shows active\/reactive energy, three-phase voltage, current, power factor, frequency, and more.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRS485 Communication:\u003c\/strong\u003e Industry-standard RS485 interface enables seamless integration with SCADA systems, building management systems (BMS), and data loggers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e35mm DIN Rail Mounting:\u003c\/strong\u003e Quick and easy installation on standard DIN rails — no special tools required.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClass 1 Accuracy:\u003c\/strong\u003e High-precision measurement of active energy (Class 1) and reactive energy (Class 2) for reliable billing and monitoring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED Pulse Output:\u003c\/strong\u003e Visual LED indicator plus passive pulse output for external energy counting or automation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuick Key Inquiry:\u003c\/strong\u003e Scroll through all electrical parameters instantly using the front-panel keys — no software required for on-site checks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Operating Range:\u003c\/strong\u003e Functions reliably in temperatures from -10°C to +55°C and humidity from 5% to 95% (non-condensing).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; Lightweight:\u003c\/strong\u003e Small 126×78×91mm footprint keeps panel space usage to a minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"text-align:left; padding:8px; border:1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left; padding:8px; border:1px solid #ddd;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRated Current\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e5(100)A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eInput Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eStarting Current\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0.4% Ib\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e3×230VAC ±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u0026lt;2W \/ 10VA per phase\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eClass 1 (Active), Class 2 (Reactive)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e126×78×91 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eInstallation\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e35mm Standard DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e-10°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e5%–95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eBattery Included\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1× 3-Phase Smart Bidirectional Energy Meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eImportant Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDue to lighting and screen differences, the actual product color may vary slightly from images.\u003c\/li\u003e\n  \u003cli\u003ePlease allow 1mm–1cm tolerance due to manual measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor guidance on safe electrical metering standards and practices, visit the NIST Smart Grid Resources page. For electrical safety standards in installations, refer to \u003ca href=\"https:\/\/www.osha.gov\/electrical\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOSHA Electrical Safety\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: What does \"bidirectional\" mean on this 3-phase energy meter?\u003c\/h4\u003e\n\u003cp\u003eA: Bidirectional measurement means the meter can record energy flowing in both directions — energy consumed from the grid (import) as well as energy fed back into the grid (export). This makes it especially useful for solar panel systems, battery storage setups, and any application where electricity may flow in both directions through the meter.\u003c\/p\u003e\n\u003ch4\u003eQ: How does the RS485 communication interface work with this kWh meter?\u003c\/h4\u003e\n\u003cp\u003eA: The RS485 interface is an industry-standard serial communication protocol that allows the meter to connect to external systems such as SCADA platforms, building management systems (BMS), PLCs, or data loggers. This enables remote monitoring, data logging, and automated energy management without requiring manual meter readings.\u003c\/p\u003e\n\u003ch4\u003eQ: Is this meter compatible with both 50Hz and 60Hz electrical systems?\u003c\/h4\u003e\n\u003cp\u003eA: Yes. This smart energy meter supports input frequencies of both 50Hz and 60Hz, making it compatible with electrical systems across North America, Europe, Asia, and other regions worldwide.\u003c\/p\u003e\n\u003ch4\u003eQ: Can this meter be installed without professional help?\u003c\/h4\u003e\n\u003cp\u003eA: The meter is designed for 35mm DIN rail mounting, which is straightforward for qualified electricians and electrical technicians. However, because this device is connected to three-phase mains power, installation should always be performed by a licensed electrician in compliance with local electrical codes and safety regulations.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does \\\"bidirectional\\\" mean on this 3-phase energy meter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Bidirectional measurement means the meter can record energy flowing in both directions — energy consumed from the grid (import) as well as energy fed back into the grid (export). This makes it especially useful for solar panel systems, battery storage setups, and any application where electricity may flow in both directions through the meter.\"}}, {\"@type\": \"Question\", \"name\": \"How does the RS485 communication interface work with this kWh meter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The RS485 interface is an industry-standard serial communication protocol that allows the meter to connect to external systems such as SCADA platforms, building management systems (BMS), PLCs, or data loggers. This enables remote monitoring, data logging, and automated energy management without requiring manual meter readings.\"}}, {\"@type\": \"Question\", \"name\": \"Is this meter compatible with both 50Hz and 60Hz electrical systems?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. This smart energy meter supports input frequencies of both 50Hz and 60Hz, making it compatible with electrical systems across North America, Europe, Asia, and other regions worldwide.\"}}, {\"@type\": \"Question\", \"name\": \"Can this meter be installed without professional help?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The meter is designed for 35mm DIN rail mounting, which is straightforward for qualified electricians and electrical technicians. However, because this device is connected to three-phase mains power, installation should always be performed by a licensed electrician in compliance with local electrical codes and safety regulations.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Fasteners \u0026 Electrical\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/collections\/fasteners-electrical\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"3-Phase Bidirectional Smart kWh Energy Meter | RS485\", \"item\": \"https:\/\/kujrmc-0q.myshopify.com\/products\/3-phase-bidirectional-smart-kwh-energy-meter-rs485\"}]}\u003c\/script\u003e","brand":"Vue","offers":[{"title":"EA772-380V","offer_id":48750269530304,"sku":"14:350850#EA772-380V","price":144.99,"currency_code":"USD","in_stock":true},{"title":"EA772-220V","offer_id":48750269563072,"sku":"14:350686#EA772-220V","price":144.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0772\/9338\/7968\/files\/S89687e8b394a4adb94d3c8183d5d8fddq_58f0ab45-7a54-4499-b183-f51935b8604f.webp?v=1786224816","url":"https:\/\/vueselect.com\/products\/3-phase-bidirectional-smart-kwh-energy-meter-rs485","provider":"Vue","version":"1.0","type":"link"}